Trained THS service technicians will provide rapid alloy identification using a Portable Thermo Scientific Niton XL2 100G XRF Analyzer on or off site.
The Niton XL2 provides immediate nondestructive chemical analysis of common alloy materials with unparalleled accuracy. Verification certificates are generated and provided with every analysis.
Plate and frame heat exchangers (PHEs) are critical for efficient heat transfer in industries like HVAC, food processing, and power generation. Their plates, typically ranging from 0.4mm to 1.0mm in thickness, are prone to fouling and wear, requiring regular servicing.
A common question is: Can any thickness of plate be serviced on PHEs?
Yes, PHE plates of various thicknesses can be serviced, but the process requires careful consideration to avoid damage
Understanding PHE Plate Thickness
PHE plates, often made of stainless steel or titanium, vary in thickness (e.g., 0.4mm for high-efficiency units, 0.7mm or thicker for durability. Thinner plates (0.4mm) are more delicate, while thicker plates withstand higher pressures but may be harder to clean due to complex fouling patterns.
How Are PHE Plates Serviced?
Servicing methods for PHE plates include:
Risks and Considerations by Plate Thickness
Effectiveness of Servicing Across Plate Thicknesses
Servicing restores efficiency by removing fouling, which can cause a 20% thermal efficiency loss even at paper-thin levels. CIP is effective for all thicknesses, while high-pressure cleaning suits thicker plates better. Regular servicing every 5–6 years or at 7–10 psi differential pressure prevents severe fouling
Conclusion
PHE plates of any thickness can be serviced using CIP, chemical flushing, or high-pressure jetting, but thinner plates require extra care to avoid damage. Industry leaders like T.H. Industrial Solutions offer tailored services to ensure safe, effective maintenance.
Double wall plate and frame heat exchangers (PHEs) are designed to prevent cross-contamination, making them essential for applications like potable water, food processing, and pharmaceuticals.
A common question is: Can double wall PHEs be chemically cleaned?
Yes, double wall PHEs can be effectively cleaned using chemical flushing or Clean-in-Place (CIP) methods, as confirmed by industry leaders like Heat Exchanger Ontario, ensuring efficiency and safety when performed by professionals.
What Are Double Wall PHEs?
Double wall PHEs feature two plates between fluid channels, providing a failsafe against leaks and cross-contamination, as noted by T.H. Industrial Solutions. This design ensures that if a plate develops a pinhole or crack, fluids remain separated, critical for potable water systems under municipal codes.
How Are Double Wall PHEs Chemically Cleaned?
Chemical cleaning methods for double wall PHEs include:
Effectiveness of Chemical Cleaning
Chemical cleaning is highly effective for double wall PHEs because it:
Limitations and Considerations
When to Chemically Clean Double Wall PHEs
Chemical cleaning is recommended every 5–6 years or when differential pressure reaches 7–10 psi, indicating fouling. It’s ideal for routine maintenance in potable water or food systems, ensuring compliance with safety codes.
Conclusion
Double wall PHEs can be chemically cleaned using CIP or chemical flushing, effectively removing fouling while maintaining their anti-contamination design. Industry leaders like T.H. Industrial Solutions offer expert services to ensure efficiency and safety.
Heat Exchanger Ontario, a division of T. H. Industrial Solutions Inc.'s (THS) has been servicing industrial heat exchangers and solving process problems across Canada since 2009. THS head office is located in Pickering, Ontario with a 6,000 square foot service center in Hamilton, Ontario.
Today there are fewer qualified people in this industry that know the products and understand the applications. Utilizing hands on experience and knowledge that has been gained by our THS sales and service technicians for over the past 30 years, we will take the time to understand what you require and strive to provide a prompt, educated and accurate response at a competitive price.
1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1
T 905 831-4963
76 Harlowe Road, Unit 4 - 7
Hamilton, ON L8W 3R6
T 905 318-0777
F 905-318-8422
1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1
76 Harlowe Road, Unit 4 - 7
Hamilton, ON L8W 3R6
OpenStreetMap service required
to load this map.
OpenStreetMap service required
to load this map.
We use cookies and similar technologies to improve your experience on our website.